Product Information
Cat. No. | Product Name | Size |
BCS0002 | Site-Specific Oligonucleotide Antibody Labeling Kit | 1 reaction |
Product Description
Site-Specific Oligonucleotide Antibody Labeling Kit provides an optimized strategy for a stable linkage between antibodies and oligonucleotides with a high conjugation efficiency and an ultra-fast reaction speed.
The antibody labeling strategies based on amine-NHS ester or maleimide chemistry will produce random labels. In some cases, labeling in Fab areas could block antigen binding.
This kit is based on a site-specific cysteine/disulfide chemistry strategy. The P-Linkers in this kit are inserted to disulfide bond location to re-form the disulfide bridging without affecting antibody-antigen binding. On the other side, the amine modified oligonucleotides can be labeled by the N-Linkers in this kit based on an amine-NHS ester strategy. Once the antibodies labeled with P-Linkers and the oligonucleotides labeled with N-Linkers are mixed together, the conjugation reaction reacts instantly.
This kit can be used for labeling 50~500μg antibodies, and only for 1 reaction. If you need a package for a different size, please contact our sales manager.
In this kit, the degree of labeling (DOL) of the P-linker labeled antibodies can be measured by using N-Linker labeled fluorescent dyes. If you need these fluorescent dyes, please contact our sales manager.
Packing List
Components | Concentration | Volume | Size |
P-Linker Labeling Solution (for antibodies) | 5.0 nmol/μL | 20μL | 1 tube, brown tube, brown cap |
N-Linker Labeling Solution (for oligos) | 5.0 nmol/μL | 20μL | 1 tube, brown tube, brown cap |
2× Antibody Labeling Buffer | 2× | 500μL | 1 tube, transparent tube, blue cap |
2× Oligo Labeling Buffer | 2× | 500μL | 1 tube, transparent tube, blue cap |
2× Antibody Pretreatment Buffer | 2× | 500μL | 1 tube, transparent tube, white cap |
1× Dilution Buffer | 1× | 1mL | 1 tube, transparent tube, white cap |
10× Stop Solution | 10× | 100μL | 1 tube, transparent tube, red cap |
10K, 500μL ultrafiltration tube | / | / | 1 |
Precautions
- This kit can be used for the conjugation between antibodies and oligos (10-120 bases long single-stranded oligos or up to 80 bases long double-stranded oligos). The target sites for labeling in the oligos should be amine modified which can be done in a regular Oligo synthesis lab.
- Protein stabilizers, such as BSA, in samples may affect the final yield, so please remove these stabilizers before starting.
- Non-protein stabilizers, such as Tris or glycerol, in samples may affect the final yield, so please remove these stabilizers with the ultrafiltration tube and the 1× Dilution Buffer.
- The final concentration of target antibodies in the standard reaction system of this kit should not be lower than 1mg/mL. If the initial concentration of the sample is too low, you can concentrate it with the ultrafiltration tube and the 1× Dilution Buffer, and make the concentrated sample up to over 2mg/mL.
- The molecular weight cut-off of the 10K, 500μL ultrafiltration tubes in this kit in around 10kDa, which can be applied for proteins larger than 10kDa.
- The maximum loading volume of the 10K, 500μL ultrafiltration tubes is 500μL, and the minimum loading volume is 20μL. The retention volume can be less than 5μL.
- The ultrafiltration membrane can be teared or pierced by pipette tips, so please try not to touch the ultrafiltration membrane with the shape end of the pipette tip.
Yes, the company comes with an analysis report for each batch of products
The company supports the customization of various products, welcome to consult.