AF 405 SE Microscale Antibody Labeling Kit

  • Cat. No.AFK0001
  • TypeKit
  • Size1 reaction
AF 405 SE Microscale Antibody Labeling Kit
AF 405 SE Microscale Antibody Labeling Kit
close
  • Product Details
  • Related Documents

Product Information

Cat. No.Product NameSize
AFK0001AF 405 SE Microscale Antibody Labeling Kit1 reaction


Product Parameters

Dye NameMolecular WeightExcitation Wavelength
Ex(nm)
Emission Wavelength
Em(nm)
Extinction Coefficient
[L/(cm*mol)]
Correction Coefficient
(A280/Amax)
Fluorescent color
AF 405 SE1,112.43
40242537,0000.77Near ultraviolet color


Product Description

      AF 405 SE is the 1 amino-reactive dye that can be coupled to primary amines (R-NH2) on almost any protein, antibody, or amine-modified oligonucleotide. The AF 405 SE Micro Antibody Labeling Kit provides the 1 method for rapid labeling of small amounts (20 to 100 μg) of antibody using AF 405 SE. Antibody labeling can usually be completed within 2 hours, and the manual operation time is about 30 minutes. The labeled antibody can be rapidly desalted and purified by ultrafiltration membrane, and the recovery rate is usually 60% ~ 90%.


Packing List

ComponentsConcentrationVolumeSize
AF 405 SE Working fluid1.0 nmol/μL20μL1 tube,brown tube,brown cap
2× AF 405 SE Reaction buffer100μL1 tube,transparent tube,blue cover
1× Dilution buffer500μL1 tube,transparent tube,white cover
10× Stop buffer10×50μL1 tube,transparent tube,red cover
10K, 500μL Ultrafiltration tube//1


Precautions

- The AF 405 SE trace antibody labeling kit is compatible with low concentrations of glycerol, Tris and thimerosal, but stable proteins must be removed from the sample before labeling.

- The molar ratio of dye to antibody molecules in a standard AF 405 SE labeling step has been optimized to label 50 μg of IgG antibody with a DOL in the range of 2 to 6. Therefore, before labeling, it is necessary to confirm the amount of μg of IgG to be labeled.

- In the standard reaction system of this kit, the final concentration of IgG should not be less than 1 mg/mL. If you need a higher DOL, you may need to adjust the molar ratio of dye to antibody molecules in the reaction system.

- The 2 × AF 405 SE reaction buffer provided in this kit has been optimized according to the characteristics of AF 405 SE. Therefore, it is not recommended to mix with other activated ester micro antibody labeling kits in the same series, which may cause the final DOL to be inconsistent with expectations.

- If you need bulk purchase or other specifications of this kit, you can inquire.

Related Products
FAQ

Yes, the company comes with an analysis report for each batch of products

The company supports the customization of various products, welcome to consult.

Yes, we can provide samples after placing an order

+86 512 67298826
  • Qrcode

    Manager Lu18362736473

  • Qrcode

    Manager Yang19906255203